6.  The stability of the power system is not affected by


   A. Generator reactance

   B. Line reactance

   C. Excitation of generators

   D. Line losses


✔ View Answer


D. Line losses

✍ Your Comments

Your name:

Your Email:

Your Comments:



7.  The Power Systems are operated with power angle around


   A. 10o

   B. 30o

   C. 70o

   D. 80o


✔ View Answer


B. 30o

✍ Your Comments

Your name:

Your Email:

Your Comments:



8.  Power system stability is defined as


   A. That attribute of the system or part of the system which enables it to develop restoring forces between the elements there of equal or greater than disturbing forces so as to restore a state of equilibrium between the elements

   B. The maximum power flow possible through some particular point in the system when the entire or part of the system is disturbed

   C. Both A and B

   D. Neither A or B


✔ View Answer


A. That attribute of the system or part of the system which enables it to develop restoring forces between the elements there of equal or greater than disturbing forces so as to restore a state of equilibrium between the elements

✍ Your Comments

Your name:

Your Email:

Your Comments:



9.  Stability limit of a power system is defined as


   A. That attribute of the system or part of the system which enables it to develop restoring forces between the elements there of equal or greater than disturbing forces so as to restore a state of equilibrium between the elements

   B. The maximum power flow possible through some particular point in the system when the entire or part of the system is disturbed

   C. Both A and B

   D. Neither A or B


✔ View Answer


B. The maximum power flow possible through some particular point in the system when the entire or part of the system is disturbed

✍ Your Comments

Your name:

Your Email:

Your Comments:



10.  Steady-state stability of a power system is the ability of the power system to


   A. Maintain voltage at the rated voltage level

   B. Maintain frequency exactly at 50 Hz

   C. Maintain a spinning reserve margin at all times

   D. Maintain synchronism between machines and on external tie lines


✔ View Answer


D. Maintain synchronism between machines and on external tie lines

✍ Your Comments

Your name:

Your Email:

Your Comments: